AnaCom's series of Super Extended
C-Band VSAT transceivers are available in transmitter output levels
of 0 dBm, 2, 5, 10, 20, 30, 40, 50, 60, 70, 80, 100, 125, 150, 180, 200, and 400
Watts, in single or redundant configurations. Higher powers
are available with external HPAs. These transceivers are ruggedly
built for continuous outdoor duty in all types of environments.
They are especially suitable for SCPC, MCPC and DAMA applications.
Features
 | Easy to install. |
 | No indoor equipment required. |
 | Built in test facilities for improved maintainability and reduced dependence on external test equipment. |
 | Compliant INTELSAT specifications and relevant CCITT and CCIR recommendations. |
 | Frequency agile radio equipment. Completely independent TX and RX frequency selection. |
 | Superior phase noise, compliant to IESS 308 /309. |
 | Auto ranging power supply. |
Flexible Applications
 | Rural Telecommunications Expansion |
 | Industrial Networking |
 | LAN and WAN extensions |
 | Emergency link restoration |
 | Remote Surveillance |
 | Broadcast |
 | Data distribution and collection |
 | Point-of-Sales Systems |
 | Video teleconferencing |
 | Conventional Voice Traffic |
Compact, Functional Design
AnaCom's extended C-Band VSAT transceivers integrate all necessary functions into a small, highly integrated out-door package which provides excellent reliability in a wide range of environments and functions.
|
 |
AnaCom, Inc.
SUPER EXTENDED C-BAND VSAT
TRANSCEIVER SERIES
0 dBm, 2, 5, 10, 20, 30, 40, 50, 60, 70, 80, 100, 125, 150, 180, 200, and 400 Watts
The up converter, down converter, power amplifier, monitor and control and power supply
are included in a single enclosure. The only cabling required to the indoor equipment are IF cables.
The LNC connects to the transceiver with a single coaxial cable.
An ovenized, high stability crystal oscillator is used to
lock the TX and RX synthesizers. The onboard microprocessor
is used to give additional temperature and aging compensation.
BITE Facility
To improve and simplify maintenance routines, an
external terminal (or computer) can be connected to monitor
a number of critical parameters without use of additional
test equipment. These include:
 | Transmitter power output level |
 | Power supply voltages |
 | TX and RX local oscillator stresses |
 | Internal temperature |
 | Alarm details |
Controllable functions from the terminal include:
 | TX frequency |
 | RX frequency (independent from TX) |
 | TX gain |
 | RX gain |
 | RF inhibit |
Comprehensive Monitor & Control
A powerful Monitor and Control feature allows you
to monitor and control the transceiver on the same M&C bus
with most indoor equipment such as modems and
multiplexers. The Monitor & Control system can be used in
combination with the unit's internal metering function to
monitor operational parameters.
MS DOS and Windows®-based
Supervisor M & C software is provided for use in combination with a PC for
monitoring and controlling all major earth station equipment besides the transceiver.
|