AnaCom, Inc.
About AnaCom
Sales
Service
News
Products

1+1 Protection Switches
Anasat Ku Band Transceiver
Anasat EKu Band Transceiver
Anasat SEKu Band Transceiver
Anasat EC
Anasat PC Band Transceiver
Anasat XC Band Transceiver
Anasat RC Band Transceiver
Anasat SEC Band Transceiver
Software link

Click here to give feedback
Products

C band
AnaCom's series of Extended C-Band VSAT transceivers are available in transmitter output levels of 0 dBm, 2, 5, 10, 20, 30, 40, 50, 60, 70, 80, 100, 125, 150, 180, 200, and 400 Watts, in single or redundant configurations. Higher powers are available with external HPAs. These transceivers are ruggedly built for continuous outdoor duty in all types of environments. They are especially suitable for SCPC, MCPC and DAMA applications.

Features
text bulletEasy to install.
text bulletNo indoor equipment required.
text bulletBuilt in test facilities for improved maintainability and reduced dependence on external test equipment.
text bulletCompliant INTELSAT specifications and relevant CCITT and CCIR recommendations.
text bulletFrequency agile radio equipment. Completely independent TX and RX frequency selection.
text bulletSuperior phase noise, compliant to IESS 308 /309.
text bulletAuto ranging power supply.

Flexible Applications
text bulletRural Telecommunications Expansion
text bulletIndustrial Networking
text bulletLAN and WAN extensions
text bulletEmergency link restoration
text bulletRemote Surveillance
text bulletBroadcast
text bulletData distribution and collection
text bulletPoint-of-Sales Systems
text bulletVideo teleconferencing
text bulletConventional Voice Traffic

Compact, Functional Design
AnaCom's
extended C-Band VSAT transceivers integrate all necessary functions into a small, highly integrated out-door package which provides excellent reliability in a wide range of environments and functions.

anacom bug AnaCom, Inc.

EXTENDED C-BAND VSAT TRANSCEIVER SERIES
0 dBm, 2, 5, 10, 20, 30, 40, 50, 60, 70, 80, 100, 125, 150, 180, 200, and 400 Watts

The up converter, down converter, power amplifier, monitor and control and power supply are included in a single enclosure. The only cabling required to the indoor equipment are IF cables. The LNC connects to the transceiver with a single coaxial cable.

An ovenized, high stability crystal oscillator is used to lock the TX and RX synthesizers. The onboard microprocessor is used to give additional temperature and aging compensation.

BITE Facility
To improve and simplify maintenance routines, an external terminal (or computer) can be connected to monitor a number of critical parameters without use of additional test equipment. These include:
text bulletTransmitter power output level
text bulletPower supply voltages
text bulletTX and RX local oscillator stresses
text bulletInternal temperature
text bulletAlarm details

Controllable functions from the terminal include:
text bulletTX frequency
text bulletRX frequency (independent from TX)
text bulletTX gain
text bulletRX gain
text bulletRF inhibit

Comprehensive Monitor & Control
A powerful Monitor and Control feature allows you to monitor and control the transceiver on the same M&C bus with most indoor equipment such as modems and multiplexers. The Monitor & Control system can be used in combination with the unit's internal metering function to monitor operational parameters.

MS DOS and Windows®-based Supervisor M & C software is provided for use in combination with a PC for monitoring and controlling all major earth station equipment besides the transceiver.


Benefits
text bulletA family of products with significant commonality minimizes demands for spares and training.
text bullet"Last Touch" controls allow for remote configuration or local (manual) configuration.
text bulletFlash memory means that the transceiver always powers up with exactly the same operating conditions as when it lost power (or was turned off).
text bulletComprehensive maintenance features for operational effectiveness and minimum outages.
text bulletSimple installation.
text bulletManufactured using state-of-the-art technology.

------------------------------
Additional Information

AnaSat EC Specifications (HTML format)

PDF icon 0dBm to 30W Datasheet
(PDF: 45.3 KB)

PDF icon 40W Datasheet
(PDF: 44.6 KB)

PDF icon 50W to 80W Datasheet
(PDF: 44.9 KB)

PDF icon 100W Datasheet
(PDF: 44.6 KB)

PDF icon 125W to 200W Datasheet
(PDF: 70 KB)

PDF icon 400W Datasheet
(PDF: 70 KB)

Diagrams: C-Band Transceivers

PDF icon 0dBm C-Band Transceiver
(PDF: 76 KB)

PDF icon 2/5 WATT C-Band Transceiver
(PDF: 75 KB)

PDF icon 10 WATT C-Band Transceiver
(PDF: 48 KB)

PDF icon 20 WATT C-Band Transceiver
(PDF: 75 KB)

PDF icon 40 WATT C-Band Transceiver
(PDF: 48 KB)

PDF icon 50/60 WATT C-Band Transceivers
(PDF: 60 KB)

PDF icon 70/80 WATT C-Band Transceivers
(PDF: 60 KB)

PDF icon 100 WATT C-Band Transceiver
(PDF: 55 KB)

PDF icon 125W, 150 WATT C-Band Transceiver
(PDF: 115 KB)

PDF icon 180W, 200 WATT C-Band Transceiver
(PDF: 115 KB)

PDF icon 400 WATT C-Band Transceiver
(PDF: 91 KB)


Operation Manuals

PDF icon Anasat C-Band QuickStart Guide
(PDF: 22 KB)

PDF icon Anasat C-Band Operations Manual
(PDF: 3.1 MB)

 

-------------------
Get Acrobat Reader If you experience difficulty reading PDF files, please download the most recent version of Acrobat Reader

 